Cooling

Moving heat from AI chips through liquid loops to the outside air

Heat (est.) Spend (est.)

Every new rack forces the air-to-liquid switch; CDU and cold-plate capacity is allocated, and the segment has drawn the most M&A of any AI-infrastructure niche.

AI racks need a thermal chain from chip cold plates and coolant distribution units to chillers, heat exchangers and outdoor heat rejection. Component compatibility, coolant cleanliness, service coverage and available water determine which systems a facility can deploy.

Why now

Blackwell-scale deployments and Rubin preparation are pushing rack heat loads beyond conventional air cooling. In 2026 suppliers are expanding megawatt CDUs and factories, while acquisitions combine chip cooling, facility equipment and water chemistry.

Facility CDUs & liquid systems

Row and plant-scale systems separate clean server coolant from facility water. Hyperscalers and colocation operators select capacity, redundancy, water temperature and service support.

Heat (est.)
  1. CoolChip CDU 2300 supplies 2.3 MW liquid-to-liquid cooling; CoolChip row manifolds connect the facility loop

    leader
    VRT · USExposure
  2. Motivair MCDU-70 delivers 2.5 MW; six units support a 10 MW cooling block with 4+2 redundancy

    leader
    SU.PA · Euronext Paris · FRExposure
  3. CoolIT CHx2000 delivers 2 MW and supports up to twelve GB300 NVL72 racks; acquisition closed July 2026

    major
    ECL · USExposure
  4. Boyd Thermal ROL2300 in-row CDU provides 2.3 MW; acquired thermal business joined Eaton in March 2026

    major
    ETN · IEExposure
  5. RackChiller and CX121 row CDUs support liquid-cooled racks; also develops Google's Project Deschutes architecture

    major
    NVT · GBExposure
  6. GoCool-3000 liquid-to-liquid CDU; Daikin partnership integrates 100 kW to 3 MW cooling across ASEAN-Oceania

    major
    2308.TW · TWSE · TWExposure
  7. Silent-Aire in-row CDUs span 500-1,050 kW; gallery skid configurations scale to 10 MW

    major
    JCI · IEExposure
  8. LiquidStack direct-to-chip CDU portfolio joins Trane's facility cooling after March 2026 acquisition

    major
    TT · IEExposure
  9. Airedale in-row and skid CDUs scale from 400 kW to 2 MW alongside chiller and control systems

    major
    MOD · USExposure
  10. Daleville campus manufactures CDUs with CRAHs and Geoclima chillers for integrated data center cooling

    major
    MTRS.ST · Nasdaq Stockholm · SEExposure
  11. 600 kW CDU gained Nvidia quality certification in July 2026; larger capacities remain in qualification

    challenger
    066570.KS · KRX · KRExposure
  12. FlaktGroup Liquid-DENCO CDUs provide redundant pumps, leak detection and secondary-loop filtration

    challenger
    005930.KS · KRX · KRExposure
  13. Chilldyne negative-pressure direct-to-chip systems combine with DDC high-density cooling cabinets

    major
    6367.T · TSE · JPExposure
  14. JetCool SmartSense modular CDUs cool 300 kW per rack and more than 2 MW at row scale

    challenger
    FLEX · USExposure
  15. CyberCool CDU isolates facility and technology cooling loops; published variants reach about 1.5 MW

    major
    Private · DEExposure
  16. DLC in-row CDU supplies 1 MW with redundant pumping for hyperscale facility-water integration

    major
    Private · DEExposure
  17. X-series row CDUs and full-chain liquid cooling connect Chinese high-density computing racks to facility loops

    major
    002837.SZ · SZSE · CNExposure
  18. Nortek CDUs span 300 kW to more than 1.2 MW, with modular pumps, 2N redundancy and hot-swappable field service

    major
    MAIR · USExposure
  19. ACM liquid cooling and 600-2,500 kW CDU systems support cold-plate and immersion deployments

    challenger
    301018.SZ · SZSE · CNExposure
  20. BASX adds coolant distribution units to its data center air-handler, chiller and fan-wall portfolio

    challenger
    AAON · USExposure
  21. In-row CDU lineup includes 2 MW-class systems and Google Project Deschutes cooling-loop integration

    major
    6594.T · TSE · JPExposure
  22. LCS-SCDU-1K3LR001 in-row CDU removes up to 1.8 MW from direct-liquid-cooled server loops

    major
    SMCI · USExposure
  23. KR1000 in-row CDU is rated at 850 kW, combining brazed plate heat exchange with redundant coolant circulation

    challenger
    8996.TW · TWSE · TWExposure
  24. CDUs and facility distribution units scale to 16 MW for liquid-cooled campuses; Lite-On's proposed 25% stake is minority

    challenger
    Private · PLExposure

Sources: vertiv.com, coolitsystems.com, se.com, lge.co.kr, nidec.com, supermicro.com

Cold plates & rack cooling

Thermal modules, manifolds and rack cooling hardware sit closest to processors. Server OEMs and rack integrators buy qualified assemblies that meet pressure, cleanliness and mechanical limits.

Heat (est.)
  1. Copper microchannel cold plates and liquid thermal modules cool Nvidia GB200 and GB300 server platforms

    leader
    3017.TW · TWSE · TWExposure~40–50% of GB200/GB300 cold plates, Apr 2026 (est.)
  2. NVIDIA MGX cold plates and coolant manifolds turn modular rack designs into deployable liquid-cooled systems

    leader
    Private · TWExposure
  3. CoolIT processor cold plates, manifolds and rack liquid loops complement its row-based CHx CDUs

    major
    ECL · USExposure
  4. Boyd Thermal liquid cold plates and manifolds complete the chip-side portion of its cooling portfolio

    major
    ETN · IEExposure
  5. AI server cold plates, CDMs, QDs and rack liquid cooling modules; expands thermal production in Thailand

    major
    3324.TWO · TPEx · TWExposure
  6. Cold plates and 250 kW in-rack CDUs integrate with its rack thermal and facility cooling products

    major
    2308.TW · TWSE · TWExposure
  7. Microchannel liquid cooling modules and precision heat spreaders manage concentrated processor hot spots

    major
    3653.TW · TWSE · TWExposure
  8. Mikros Normal Flow microchannel cold plates and custom manifolds integrate into OEM rack cooling assemblies

    major
    JBL · USExposure
  9. JetCool SmartPlate liquid cooling for Dell PowerEdge R770 and R7725 supports Xeon 6 and fifth-generation EPYC

    major
    FLEX · USExposure
  10. Alloy Enterprises Stack Forging cold plates add embedded microgeometries; acquisition closed May 2026

    challenger
    JCI · IEExposure
  11. Cold-plate cooling removes heat from its 800 VDC power rack, demonstrated with QCT at COMPUTEX 2026

    challenger
    2301.TW · TWSE · TWExposure
  12. Custom CPU/GPU cold plates and round or square coolant manifolds connect server liquid-cooling loops

    niche
    6125.TWO · TPEx · TWExposure
  13. EC fans and airflow modules remove residual rack heat alongside liquid-to-air cooling assemblies

    challenger
    2421.TW · TWSE · TWExposure
  14. USystems ColdLogik rear-door heat exchangers serve Cambridge's GPU racks and direct-liquid-cooling retrofit

    major
    LR.PA · Euronext Paris · FRExposure
  15. 70 kW rear-door heat exchangers remove rack exhaust heat without replacing the facility's room cooling system

    major
    Private · DEExposure
  16. LiquidJet cold plates demonstrated at 1,400 W Blackwell Ultra and 1,950 W Rubin heat loads; qualification not assumed

    emerging
    Private · USExposure
  17. Microfluidic cold-plate prototypes tested with Microsoft; production-server deployment is not established

    emerging
    Private · CHExposure
  18. AMD SP5 Genoa/Turin server thermal modules support 350-500 W CPUs alongside cold-plate liquid cooling

    niche
    3338.TW · TWSE · TWExposure
  19. Direct-to-chip cold plates and server thermal modules transfer CPU and GPU heat into the liquid loop

    niche
    3483.TWO · TPEx · TWExposure
  20. Double-sided cold plate demonstrated at 6 kW with liquid-metal TIM at COMPUTEX 2026; production qualification is separate

    challenger
    6669.TW · TWSE · TWExposure
  21. Microdeformation cold plates form fine copper structures for CPU and GPU liquid-cooling heat transfer

    niche
    Private · DEExposure
  22. HPC server thermal modules combine heat sinks, heat pipes and vapor chambers within the separately listed Nidec affiliate

    niche
    6230.TW · TWSE · TWExposure
  23. Designs hyperscaler cold plates and manifolds for AI racks, with custom liquid-cooling thermal assemblies

    challenger
    CLS · CAExposure
  24. Single- and two-phase server cold plates, TIM materials and fans are disclosed in its H1 2026 thermal-management portfolio

    challenger
    300602.SZ · SZSE · CNExposure

Sources: coolermaster.com, jabil.com, flex.com, nidec.com, celestica.com, static.cninfo.com.cn

Chillers & precision air

Chillers, computer-room air handlers and fan walls maintain facility water and room temperatures. Reliability, hot-weather capacity, refrigerants and local manufacturing decide large campus orders.

Heat (est.)
  1. YORK YVAM and 3.5 MW YDAM magnetic-bearing chillers serve AI campuses; the applied-chiller business remains with JCI

    leader
    JCI · IEExposure~21% of global DC chiller revenue, 2025 (est.)
  2. Centrifugal and air-cooled chillers anchor integrated plants; Stellar Energy Digital adds packaged cooling

    leader
    TT · IEExposure~19% of global DC chiller revenue, 2025 (est.)
  3. QuantumLeap suite includes AquaEdge 30CF, AquaForce 30XV and water-cooled centrifugal chillers

    major
    CARR · USExposure~15% of global DC chiller revenue, 2025 (est.)
  4. Airedale chillers and precision air systems underpin a $4 billion customer capacity agreement for 2027-2029

    major
    MOD · USExposure
  5. Applied chiller plants and DDC high-density cabinets link central cooling to AI server rooms

    major
    6367.T · TSE · JPExposure~12% of global DC chiller revenue, 2025 (est.)
  6. Liebert room and row cooling plus chiller systems remove residual air heat around liquid-cooled AI racks

    major
    VRT · USExposure~8% of global DC chiller revenue, 2025 (est.)
  7. FlaktGroup DENCO precision cooling, fan walls and chillers now sit within Samsung after November 2025 closing

    major
    005930.KS · KRX · KRExposure
  8. Centrifugal chillers and fan-wall units complement its CDU line; Microsoft cooling work remains validation-stage

    challenger
    066570.KS · KRX · KRExposure
  9. BASX free-cooling chillers, CRAHs and fan walls supply Applied Digital's purpose-built AI campus

    major
    AAON · USExposure
  10. Geoclima Circlemiser chillers, CRAHs and SyCool systems now share expanded Daleville manufacturing capacity

    major
    MTRS.ST · Nasdaq Stockholm · SEExposure
  11. MEHITS MECH-iC magnetic-bearing chillers launch in 350- and 500-ton models for US hyperscale sites

    major
    6503.T · TSE · JPExposure
  12. 10 MW centrifugal chiller test unit shipped to the US in 2026; certification precedes commercial deployment

    challenger
    7011.T · TSE · JPExposure
  13. CyberAir precision room cooling and CyberCool chillers support mission-critical data center thermal systems

    major
    Private · DEExposure
  14. Uniflair room cooling and Motivair chillers serve facility-water and residual-air cooling requirements

    major
    SU.PA · Euronext Paris · FRExposure
  15. Clivet magnetic chillers with INTELLIPLANT controls address large data center cooling plants

    challenger
    0300.HK · HKEX · CNExposure
  16. CVT centrifugal chillers and modular cooling stations supplied Huawei Dongguan; this is a historical campus reference

    niche
    000651.SZ · SZSE · CNExposure
  17. Geniox Tera fan-wall units supply a Finnish hyperscale campus under an August 2026 order for delivery in 2027

    niche
    SYSR.ST · Nasdaq Stockholm · SEExposure
  18. Swegon BlueBox chillers and free-cooling systems regulate facility water for data center thermal plants

    niche
    LATO-B.ST · Nasdaq Stockholm · SEExposure
  19. Magnetic-bearing centrifugal chillers anchor the central cooling plant in its 2026 AIDC thermal offering

    niche
    6690.HK · HKEX · CNExposure
  20. Dunham-Bush applied chillers and DBAire precision air systems cool data center water loops and server rooms

    niche
    000811.SZ · SZSE · CNExposure
  21. UniCool-Max air cooling provides 60 kW per unit and up to 960 kW per controlled cluster for modular data centers

    niche
    Private · USExposure
  22. Vindur CoolWall supplies precision air cooling for data halls with rack densities up to 50 kW

    niche
    Private · DEExposure
  23. Fan-wall units and computer-room air conditioning remove data hall heat alongside its clean-environment systems

    niche
    011930.KS · KRX · KRExposure
  24. Absorption chillers use heat-driven cooling; management disclosed an order for 23 units for US data centers

    niche
    THERMAX.NS · NSE · INExposure

Sources: johnsoncontrols.com, carrier.com, investors.modine.com, businesswire.com, gminsights.com, group.systemair.com

Heat rejection & thermal storage

Heat exchangers transfer heat from racks and coolant circuits into facility water; towers and dry coolers reject it outdoors. Buyers select approach temperature, water use, footprint and integration with high-density thermal loops.

Heat (est.)
  1. CB brazed exchangers power Boyd's ROL2300 CDU; FreeWaterLoop combines facility heat exchange, pumps and filtration

    leader
    ALFA.ST · Nasdaq Stockholm · SEExposure
  2. Marley NC and MD Everest cooling towers and dry/fluid coolers reject heat from high-density data centers

    leader
    SPXC · USExposure
  3. SWEP brazed plate heat exchangers serve CDUs, chillers and heat-recovery loops; capacity expansion announced in 2026

    major
    DOV · USExposure
  4. ThermoKey dry coolers and heat exchangers extend outdoor heat rejection; acquisition completed in June 2026

    major
    VRT · USExposure
  5. TrilliumSeries dry coolers and FXV3 closed-circuit towers address data center heat rejection

    major
    Private · USExposure
  6. eco-ATWB and eco-ATWB-H hybrid closed-circuit coolers balance dry operation with evaporative capacity

    major
    Private · USExposure
  7. High Density dry coolers with hydroBLU adiabatic control adjust water use to outdoor conditions

    major
    Private · DEExposure
  8. Data center dry coolers and heat exchangers remain under Apollo control pending the announced SLB transaction

    major
    Private · DEExposure
  9. AlfaBlue heavy-duty dry coolers reject facility-loop heat for data center applications

    major
    LUVE.MI · Borsa Italiana · ITExposure
  10. Brazed plate heat exchangers separate data center liquid loops and integrate into its server CDUs

    major
    8996.TW · TWSE · TWExposure
  11. Airedale dry coolers and free-cooling chillers support higher-temperature AI facility water loops

    major
    MOD · USExposure
  12. SyCool Split and air-side economizers discharge data center heat while reducing compressor operation

    major
    MTRS.ST · Nasdaq Stockholm · SEExposure
  13. BASX free-cooling heat-rejection chillers integrate with fan coils and custom campus thermal systems

    major
    AAON · USExposure
  14. StatePoint membrane-based heat rejection supplies chilled water at Digital Edge's 10 MW Manila facility

    major
    MAIR · USExposure
  15. Heat exchangers serve data center condensers, evaporators, free-cooling circuits and CDUs

    challenger
    2050.HK · HKEX · CNExposure
  16. Geniox Tera I indirect and Tera D direct free-cooling units remove facility heat with 300-400 kW modular blocks

    major
    SYSR.ST · Nasdaq Stockholm · SEExposure
  17. Swegon Blue Box external free-cooling systems and dry coolers reject data center heat through facility water loops

    major
    LATO-B.ST · Nasdaq Stockholm · SEExposure
  18. The Roberts Company fabricates thermal expansion and energy-storage tanks under a $125 million data center contract

    niche
    AGX · USExposure
  19. SIGMA M186 gasketed plate exchanger provides more than 15 MW of heat transfer for data center cooling loops

    niche
    Private · USExposure
  20. SPX FLOW's APV plate heat exchangers transfer data center heat between cooling-water circuits

    niche
    ITT · USExposure
  21. Hybrid closed-loop cooling towers reject facility heat; management disclosed an Indian data center order in 2026

    niche
    THERMAX.NS · NSE · INExposure
  22. XFlex modular evaporative cooling rejects data center heat through integrated air and water circuits

    major
    002837.SZ · SZSE · CNExposure
  23. Evaporative data center cooling systems transfer facility heat outdoors alongside its ACM liquid-cooling equipment

    challenger
    301018.SZ · SZSE · CNExposure
  24. PowerCool enclosed rear-door heat exchanger provides up to 80 kW per rack for PowerEdge systems

    challenger
    DELL · USExposure

Sources: alfalaval.com, spxcooling.com, dovercorporation.com, baltimoreaircoil.com, apiheattransfer.com, dell.com

Pumps, valves & couplings

Coolant pumps, pipes and non-spill connectors maintain flow through facility loops and racks. Buyers qualify materials, pressure drop, leak performance and interoperability before volume deployment.

Heat (est.)
  1. Energy Valve and EPIV devices regulate flow and monitor heat transfer in CDUs, cold plates and CRAHs

    major
    BEAN.SW · SIX · CHExposure
  2. COOL-FIT insulated piping and LiquidCore distribution connect chillers, CDUs and rack manifolds

    major
    GF.SW · SIX · CHExposure
  3. FreeWaterLoop integrates facility circulation pumps, filtration and heat exchange into one cooling system

    major
    ALFA.ST · Nasdaq Stockholm · SEExposure
  4. Bell & Gossett hydrovar X pump systems circulate water through data center towers and direct-to-chip loops

    major
    XYL · USExposure
  5. TPE2/TPE3 pumps and distributed pumping systems serve data center cooling, including QNB Finansbank

    leader
    Private · DKExposure
  6. Stratos GIGA B pumps operate at Iron Mountain Haarlem; GIGA2.0 and Helix systems serve cooling loops

    major
    Private · DEExposure
  7. EtaSeco sealed pumps serve CDUs while Etanorm circulation pumps support facility cooling circuits

    major
    KSB.DE · XETRA · DEExposure
  8. Design Envelope pumps and EVERCOOL controls automate redundant data center chiller and cooling-tower loops

    major
    Private · CAExposure
  9. EPAC develops dedicated pump specifications for US data center chiller manufacturers

    niche
    6361.T · TSE · JPExposure
  10. Pegler pressure-independent valves and VSH Shurjoint connections regulate primary and secondary cooling loops

    major
    AALB.AS · Euronext Amsterdam · NLExposure
  11. TA-Smart valves stabilize data center water flow while measuring temperatures and thermal energy

    major
    IMI.L · LSE · GBExposure
  12. iDROSET CSD balancing valves and industrial strainers regulate data center process-cooling water and protect sensitive pumps

    major
    WTS · USExposure
  13. SPX FLOW's Johnson Pump Combiflex units circulate coolant through facility thermal-management loops

    niche
    ITT · USExposure
  14. Fisher and Keystone control and isolation valves regulate data center chilled-water and condenser-water systems

    major
    EMR · USExposure
  15. Electric valve actuators automate chilled-water isolation and flow control in data center cooling systems

    niche
    ROR.L · LSE · GBExposure
  16. Magnetic-drive pumps circulate coolant in data center cooling equipment while sealing the motor from the liquid

    niche
    6237.T · TSE · JPExposure
  17. Butterfly valves isolate chillers, CDUs and heat exchangers in data center cooling-water circuits

    niche
    MWA · USExposure
  18. Aurora 3800-series pumps circulate chilled and condenser water in data center cooling plants

    major
    PNR · GBExposure

Sources: dovercorporation.com, parker.com, danfoss.com, emerson.com, iwakiamerica.com, pentair.com

Immersion & two-phase cooling

Immersion encloses whole servers in dielectric fluid; two-phase direct-to-chip systems boil coolant at cold plates. Adoption depends on server warranties, service practices and validated fluids.

Heat (est.)
  1. SmartPod and SmartPod EXO immersion systems package high-density servers in dielectric cooling tanks

    leader
    Private · ESExposure
  2. ICEraQ immersion tanks and 13 kW ICEraQ Nano edge systems; integrated cooling pilots with LG and SK Enmove

    major
    Private · USExposure
  3. Acquired LiquidStack DataTank and EdgeTank immersion systems extend its thermal portfolio beyond chillers

    major
    TT · IEExposure
  4. Controlled Accelsius sells NeuCool MR250 two-phase cooling for 250 kW racks; 2026 revenue guidance is suspended

    emerging
    INV · USExposure
  5. HyperCool waterless two-phase cold-plate platform gains further Carrier Ventures backing in April 2026

    challenger
    Private · USExposure
  6. KUL AI chassis-level precision immersion supports up to 100 kW heat rejection in a rack-compatible format

    niche
    Private · GBExposure
  7. AIC24N immersion systems operate at Bytesnet Groningen, Credit Agricole Chartres and Ecoracks Eindhoven

    niche
    Private · NLExposure
  8. Single-phase immersion cabinets and matching CDUs form part of its Chinese full-chain liquid cooling portfolio

    major
    002837.SZ · SZSE · CNExposure
  9. Offers immersion tanks and cold-plate liquid-cooling systems; disclosed product capability does not establish site volumes

    challenger
    300499.SZ · SZSE · CNExposure
  10. Immersion tank and coolant integration is in joint PoC with GRC and SK Enmove at the Pyeongtaek chiller site

    emerging
    066570.KS · KRX · KRExposure
  11. Server immersion enclosures and FDUs support whole-system cooling; Lite-On's proposed stake is minority

    challenger
    Private · PLExposure
  12. QuantumLeap integrates ZutaCore HyperCool two-phase cooling; Carrier Ventures increased its minority stake in April 2026

    emerging
    CARR · USExposure
  13. White-label sales alliance integrates ZutaCore HyperCool two-phase cold plates with facility thermal and power systems

    challenger
    7011.T · TSE · JPExposure
  14. SmartBox immersion tanks combine Databean technology with its thermal systems; 12U, 25U and 50U products target pilots

    emerging
    011930.KS · KRX · KRExposure
  15. ORv3 server tested in Intel Open IP single-phase immersion tank with Perstorp POE390z fluid in April 2026

    emerging
    6669.TW · TWSE · TWExposure
  16. DUG Cool immersion technology is licensed exclusively to Baltimore Aircoil; DUG Nomad packages immersion-cooled HPC

    niche
    DUG.AX · ASX · AUExposure
  17. Exclusive license commercializes DUG Cool immersion technology as an extension to facility heat-rejection equipment

    emerging
    Private · USExposure

Sources: investors.tranetechnologies.com, submer.com, grcooling.com, ir.innventure.com, dug.com, wiwynn.com

Fluids & water treatment

Water chemistry protects narrow cold-plate channels; dielectric fluids enable immersion and two-phase cooling. Qualification covers corrosion, materials compatibility, lifetime stability and environmental rules.

Heat (est.)
  1. Nalco Water 3D TRASAR monitors direct-to-chip coolant; Cooling as a Service combines chemistry and CDU management

    leader
    ECL · USExposure
  2. LC 25 coolant in the DOWFROST family uses inhibited propylene glycol for copper-rich direct-to-chip loops

    major
    DOW · USExposure
  3. Developmental Opteon 2P50 fluid targets two-phase immersion; customer qualification precedes commercial deployment

    emerging
    CC · USExposure
  4. Solstice refrigerants and two-phase fluids serve precision air conditioning and liquid cold-plate cooling

    major
    SOLS · USExposure
  5. S5 X gas-to-liquids dielectric fluid runs in Asperitas immersion systems, including Shell's Amsterdam installation

    major
    SHEL · GBExposure
  6. Castrol ON PG 25 direct-liquid coolant and DC 15/DC 20 immersion fluids; announced Castrol sale remains pending

    major
    BP · GBExposure
  7. EM DC immersion oil grades are PFAS-free; Intel collaboration develops and qualifies liquid cooling applications

    major
    XOM · USExposure
  8. DC Cooling BioLife biosourced dielectric fluids participate in GRC's ElectroSafe qualification program

    major
    TTE · FRExposure
  9. Lubrizol CompuZol IM2015, IM2020 and IM2025 fluids provide single-phase immersion cooling

    niche
    BRK-B · USExposure
  10. Data center water treatment, reuse and Hubgrade monitoring support cooling-loop operation and water conservation

    major
    VIE.PA · Euronext Paris · FRExposure
  11. Korrodex closed-loop chemistry, cooling-water treatment and precommissioning cleaning serve data center HVAC loops

    major
    6370.T · TSE · JPExposure
  12. RENOLIN FECC 10 SYN, FECC 7 and FECC 5 SYNTH are dielectric fluids for single-phase electronics cooling

    niche
    FPE3.DE · XETRA · DEExposure
  13. IX Series plant-based dielectric fluids target single-phase immersion of data center servers

    niche
    5020.T · TSE · JPExposure
  14. SK On's former Enmove business validates immersion fluids with LG cooling equipment and GRC tanks

    challenger
    096770.KS · KRX · KRExposure
  15. 50%-owned GS Caltex supplies Kixx Immersion Fluid S 30 to LG Uplus pilots; Kixx DLC Fluid PG25 targets chip loops

    challenger
    078930.KS · KRX · KRExposure
  16. Oilbank XTeer E-Cooling Fluid is in Naver Cloud immersion validation under a 2025-2028 pilot program

    emerging
    267250.KS · KRX · KRExposure
  17. e-Cooling Solution fluid enters AI server testing with KTNF and GST under their September 2026 validation agreement

    emerging
    010950.KS · KRX · KRExposure
  18. ChemTreat cooling-water chemistry and monitoring support more than 200 data center sites

    major
    VLTO · USExposure
  19. Cooling-water treatment programs control corrosion, scale and microbes; precommissioning chemistry cleans new loops

    major
    Private · USExposure
  20. ICF Series low-viscosity dielectric oils, launched in April 2025, immerse data center servers for heat removal

    niche
    5019.T · TSE · JPExposure
  21. Foranext dielectric fluids and Forane refrigerants support two-phase chip cooling and data center thermal loops

    niche
    AKE.PA · Euronext Paris · FRExposure
  22. DAISAVE SS49 fluorinated fluid provides electrically insulating heat transfer for immersion-cooled electronics

    niche
    6367.T · TSE · JPExposure
  23. Great Wall XinPai CS-S10 immersion oil and CF-B170 fluorinated fluid cool data center electronics

    niche
    0386.HK · HKEX · CNExposure
  24. Synfluid PAO base stocks from the 50%-owned Chevron Phillips Chemical JV formulate single-phase immersion fluids

    niche
    CVX · USExposure

Sources: ecolab.com, dow.com, solstice.com, chemtreat.com, idemitsu.com, solenis.com

Quick disconnects & hoses

Serviceable liquid connections join cold plates, rack manifolds and CDUs. Rack designers select leak resistance, blind-mate alignment, flow capacity and compatibility with OCP connector standards.

Heat (est.)
  1. CPC dry-break quick disconnects connect cold plates, rack manifolds and CDUs without draining entire cooling loops

    leader
    DOV · USExposure
  2. UQD and blind-mate liquid cooling couplings support OCP interoperability and serviceable rack coolant connections

    major
    PH · USExposure
  3. Hansen UQD, blind-mate and FD83 couplings plus Boston EPDM hoses carry coolant from facility loops into racks

    major
    Private · DKExposure
  4. OCP-compatible UQD non-spill connectors provide serviceable liquid connections for data centers and HPC

    major
    Private · CHExposure
  5. Data Master hoses carry coolant through dense racks and chilled-water connections where rigid piping is impractical

    major
    GTES · USExposure
  6. MQD, NVQD and NVBQD connectors couple cold plates and manifolds in AI racks; June 2026 lineup includes Nvidia MGX

    challenger
    3533.TW · TWSE · TWExposure
  7. OCP UQD hand-mate and high-flow non-drip couplings serve cold plates, rack manifolds and CDU connections

    niche
    Private · SEExposure
  8. UQD/UQDB V2, MQD and blind-mate couplings connect coolant hoses, cold plates and manifolds in AI server racks

    major
    APH · USExposure
  9. Quick disconnects serve GB200/GB300 switch trays; management reports rack-manifold shipments and further ASIC qualification

    challenger
    6805.TW · TWSE · TWExposure
  10. Tube fittings and valve assemblies connect facility cooling headers, heat exchangers and instrumentation

    niche
    Private · USExposure
  11. UQD02-08, blind-mate UQDB and MQD couplings provide detachable coolant connections for server and rack loops

    challenger
    6594.T · TSE · JPExposure

Sources: lotes.cc, amphenol-industrial.com, nidec.com

Glossary

CDU
Coolant distribution unit: controls flow and temperature while isolating the server loop from facility cooling water.
Cold plate
A liquid-cooled metal component mounted on a processor to collect heat at the source.
UQD
Universal quick disconnect: a standardized, low-spill connector used to service liquid cooling circuits.
PUE
Power usage effectiveness: total facility power divided by IT power; lower means less infrastructure overhead.
Two-phase cooling
Cooling that uses a fluid's evaporation and condensation to transport heat.

Heat, spend, exposure and shares are editorial estimates. How to read the map ↗