Data Center Power

Keeping AI facilities energized from the incoming feed to the rack distribution network

Heat (est.) Spend (est.)

UPS, switchgear and busway backlogs stretch years out, and the 800V HVDC transition rewrites the whole facility electrical stack at once.

UPS, switching equipment, on-site generation and batteries turn an electrical connection into reliable compute capacity. AI campuses increasingly combine these systems inside the fence, while higher-voltage DC designs seek to reduce conversion losses and copper demand.

Why now

Grid connection delays and sharp AI load swings drive orders for dedicated generation, switchgear and storage. Suppliers are expanding factories in 2026 while 800 VDC and solid-state transformer programs prepare for deployment mainly from 2027.

UPS & continuity systems

Static and rotary UPS protect compute against supply disturbances. Buyers choose redundancy, serviceability and efficiency at megawatt scale, with local certification shaping supplier access.

Heat (est.)
  1. Galaxy VXL 500-1,250 kW modular UPS supports live module replacement and scalable high-density power blocks

    leader
    SU.PA · Euronext Paris · FRExposure
  2. Trinergy 1.5-2.5 MVA UPS combines with PowerBoard switchgear in factory-integrated PowerNexus systems

    leader
    VRT · USExposure
  3. 9395X UPS supplies 900-1,700 kW blocks for hyperscale and colocation critical power plants

    major
    ETN · IEExposure
  4. HiPerGuard medium-voltage UPS adds a 34.5 kV direct-grid variant, with initial orders expected in 2026

    major
    ABBN.SW · SIX · CHExposure
  5. Ultron DPM Gen2 reaches 2,500 kVA at 480 V; DPS systems parallel for multi-megawatt data center loads

    major
    2308.TW · TWSE · TWExposure
  6. 9900CX 1,050-2,100 kVA and 9900D UPS supply large data center loads; TMEIC adds joint-venture power systems

    major
    6503.T · TSE · JPExposure
  7. UPS7400WX-T3U modular systems span 225-1,000 kVA for mission-critical data center power

    major
    6504.T · TSE · JPExposure
  8. G9400 modular UPS supports 1.2-2 MW installations; also owns half of the TMEIC power systems venture

    major
    Private · JPExposure
  9. Digital Power UPS5000-H 400-1,600 kVA modules integrate into FusionPower data center electrical systems

    major
    Private · CNExposure
  10. S3 integrated lithium UPS and WiseAisle 8.0, launched in August 2026, target Chinese high-density facilities

    major
    002335.SZ · SZSE · CNExposure
  11. HPM3300E modular UPS uses 100 kW, 3U power modules to scale facility backup capacity

    major
    002518.SZ · SZSE · CNExposure
  12. DELPHYS XL 1,000/1,200 kW UPS delivers modular high-power protection for large data centers

    major
    Private · FRExposure
  13. Multi Power2 modular UPS and compact M2X systems cover critical data center and edge-facility loads

    major
    Private · ITExposure
  14. UNIBLOCK UB-V rotary UPS supplies roughly 1-3.24 MW per unit without conventional static UPS architecture

    niche
    Private · DEExposure
  15. HITEC PowerPRO 2700 rotary UPS combines kinetic ride-through with engine-backed data center power

    niche
    4088.T · TSE · JPExposure
  16. StratusPower cabinets scale from 10-1,500 kW and parallel to 3.75 MW for critical data center installations

    challenger
    CNTL.SW · SIX · CHExposure
  17. Medium-voltage AI UPS has one 5 GW Crusoe deployment agreement; initial campus commissioning is planned for 2026-2027

    challenger
    Private · USExposure
  18. Keor FLEX modular UPS scales to 1.2 MW per frame and 4.8 MW in parallel for data center critical power

    major
    LR.PA · Euronext Paris · FRExposure
  19. SANUPS A23C three-phase online UPS provides up to 30 kVA for server-room and small-facility critical power

    niche
    6516.T · TSE · JPExposure

Sources: se.com, vertiv.com, eaton.com, hitec-ups.com, legrand.com, products.sanyodenki.com

Switchgear, busway & PDUs

Power rooms distribute medium and low voltage through protected circuits, busway and metered PDUs. Long manufacturing lead times make qualified production capacity and field service decisive.

Heat (est.)
  1. Square D distribution and ASCO transfer switches route critical facility feeds through redundant power paths

    leader
    SU.PA · Euronext Paris · FRExposure
  2. Power Xpert switchgear, busway and power distribution units connect facility feeds to data hall loads

    leader
    ETN · IEExposure
  3. ReliaGear neXT switchboards and MNS low-voltage assemblies provide protected data center power distribution

    major
    ABBN.SW · SIX · CHExposure
  4. SIVACON S8/8PS switchboards and busway plus Russelectric controls handle facility distribution and source transfer

    major
    SIE.DE · XETRA · DEExposure
  5. E+I switchgear and busway integrate with PowerBoard distribution; Geist PDUs meter power at cabinets

    major
    VRT · USExposure
  6. Starline busway, Raritan intelligent PDUs and Server Technology units distribute and monitor data hall power

    major
    LR.PA · Euronext Paris · FRExposure
  7. Anord Mardix switchgear, busway and PDUs combine with Crown Technical electrical equipment for hyperscale sites

    major
    FLEX · USExposure
  8. Acquired Avail EPG adds switchgear and bus systems; Trachte integrates equipment into protected electrical buildings

    major
    NVT · GBExposure
  9. PowlVac metal-clad switchgear and PCR packaged rooms combine protection and distribution for large electrical loads

    major
    POWL · USExposure
  10. MGM and VanTran transformers join PwrQ distribution and States switchgear in data center power packages

    challenger
    FPS · USExposure
  11. A $64 million US order supplies 38 kV switchgear for a data center microgrid, with delivery in 2026-2027

    challenger
    010120.KS · KRX · KRExposure
  12. EX-way busduct from LS Cable & System supplies high-current distribution inside hyperscale facilities

    major
    006260.KS · KRX · KRExposure
  13. July 2026 North American data center switchgear and power-package orders total $721 million through 2028

    challenger
    267260.KS · KRX · KRExposure
  14. Dry-type transformers serve Alibaba, Baidu and Chinese carriers; H1 2026 data center orders reached RMB 3.87 billion

    major
    688676.SS · SSE · CNExposure
  15. eSTS static transfer switches span 250-4,000 A, transferring critical loads between independent feeds

    niche
    Private · USExposure
  16. SmartZone G5 intelligent PDUs provide cabinet-level power distribution, monitoring and environmental sensing

    major
    Private · USExposure
  17. Dry-type transformers step down facility power and feed PDUs; power-quality products manage sensitive data center loads

    major
    HPS-A.TO · TSX · CAExposure
  18. Transformers, switchgear and power-management systems equip STT Seoul 1, the campus in its 40%-owned operating JV

    challenger
    298040.KS · KRX · KRExposure
  19. PASS hybrid switchgear and distribution transformers from Hitachi Energy equip data center campus substations

    major
    6501.T · TSE · JPExposure
  20. Data center substation equipment combines transformers and circuit breakers across low- and high-voltage facility feeds

    major
    6504.T · TSE · JPExposure
  21. Low-voltage distribution boards, NXA air circuit breakers and transfer switches protect redundant data center feeds

    challenger
    601877.SS · SSE · CNExposure
  22. Tallgrass ordered $99.2 million of power transformers for a US hyperscale project, with delivery over 12-20 months

    challenger
    CGPOWER.NS · NSE · INExposure
  23. Molded transformers supply data center facility distribution; disclosed orders support expansion of transformer production

    niche
    6622.T · TSE · JPExposure
  24. UL 891 switchboards and 300-1,250 kVA distribution centers route protected power to data center loads

    niche
    Private · USExposure

Sources: flex.com, investors.nvent.com, siemens.com, nsearchives.nseindia.com, trystar.com, fujielectric.com

Reciprocating generators

Diesel engines provide standby power while gas engines increasingly run dedicated campus supply. Data center duty ratings, fast load response, emissions permits and service capacity determine adoption.

Heat (est.)
  1. G3516 gas gensets underpin AIP's 2 GW Monarch order; diesel packages remain a mainstay of hyperscale backup

    leader
    CAT · USExposure
  2. QSK95 data center continuous-duty generator sets deliver roughly 2.5-3.35 MW for redundant campus backup

    leader
    CMI · USExposure~55% of India DC genset units, Jun 2026 (est.)
  3. mtu Series 4000 diesel and gas gensets include a fast-start 2.8 MW gas variant for data center duty

    major
    RR.L · LSE · GBExposure
  4. KD diesel generator portfolio reaches 4 MW per set for hyperscale and colocation backup systems

    major
    Private · USExposure
  5. 2.25-3.25 MW diesel packages use Baudouin M55 engines to enter large hyperscale standby installations

    challenger
    GNRC · USExposure
  6. Jenbacher gas engines supply VoltaGrid's 1.5 GW order, supporting dedicated power for AI campuses

    major
    INIO · DEExposure
  7. Forty 34SG engines provide a contracted 412 MW Ohio data center power plant, targeted for 2028 operation

    major
    WRT1V.HE · Nasdaq Helsinki · FIExposure
  8. Everllence supplies twenty-four 18V51/60G engines for a 480 MW off-grid US data center power project

    major
    VOW3.DE · XETRA · DEExposure
  9. Forty-five B36:45V20AG1 engines exceed 500 MW in Liberty Energy's order, with deliveries beginning in 2027

    major
    Private · NOExposure
  10. MGS diesel gensets offer data center power ratings and unrestricted consecutive operation at the required N load

    major
    7011.T · TSE · JPExposure
  11. HIMOINSA and Yanmar diesel backup systems serve data centers; a new Fukuoka production plant targets 2028

    major
    Private · JPExposure
  12. Baudouin M33 and M55 engine families span high-output data center gensets, including third-party OEM packages

    major
    2338.HK · HKEX · CNExposure
  13. Own-brand engines and the mtu JV supplied approximately 1,800 AI data center engines in the first half of 2026

    challenger
    CYD · SGExposure
  14. Gas-engine power systems serve data center demand; quarterly shipment timing remains uneven in 2026

    challenger
    PSIX · USExposure
  15. 9.6 MW HiMSEN engines underpin Corban's August 2026 1 GW US data center generation order

    challenger
    329180.KS · KRX · KRExposure
  16. EDG emergency diesel generators supply IDCs; July 2026 Dnotitia MoU targets power equipment for Changwon's defense AI center

    niche
    077970.KS · KRX · KRExposure

Sources: cummins.com, generac.com, wartsila.com, everllence.com, investor.cyilimited.com, livemint.com

Turbines & fuel cells

Aeroderivative turbines and stationary fuel cells offer alternatives to reciprocating engines for dedicated campus supply. Fuel availability, emissions, ramp behavior and equipment delivery govern project economics.

Heat (est.)
  1. Twenty-nine LM2500XPRESS aeroderivative packages supply Crusoe's contracted AI data center power buildout

    leader
    GEV · USExposure
  2. Energy Server fuel cells are planned for up to 2.45 GW at Oracle and BorderPlex's Project Jupiter

    leader
    BE · USExposure
  3. Solar Turbines gas packages supply dedicated campus power; Vertiv partnership integrates power and cooling systems

    major
    CAT · USExposure
  4. SGT-A05 gas turbines support Equinix DB5 Dublin's on-site energy system and other dedicated power configurations

    major
    ENR.DE · XETRA · DEExposure
  5. NovaLT16 orders include Dynamis and Kodiak data center power programs; Kodiak's framework reaches 1.8 GW by 2030

    major
    BKR · USExposure
  6. Thirteen 50 MW PE6000 turbine packages are ordered for Crusoe AI factories, announced in April 2026

    major
    Private · USExposure
  7. Five 380 MW gas turbines ordered by an unnamed US technology customer for data center power; delivery starts in 2027

    challenger
    034020.KS · KRX · KRExposure
  8. HyAxiom's September PAFC supply contracts total KRW 823.6 billion; the additional order ships to North America from 2028

    challenger
    336260.KS · KRX · KRExposure
  9. Packaged 12.5 MW blocks combine ten 1.25 MW fuel-cell modules; large AI campus adoption remains pre-scale

    emerging
    FCEL · USExposure
  10. Linear Generator modules provide fuel-flexible on-site generation designed for phased data center deployment

    challenger
    Private · USExposure
  11. GPS 3500 and other standby gas turbines supply 1.6-4.8 MW per unit for Japanese data centers and critical facilities

    major
    7012.T · TSE · JPExposure
  12. Mitsubishi Power's first two M501JAC turbines are allocated to Tallgrass' dedicated 1,150 MW Cheyenne campus power phase

    major
    7011.T · TSE · JPExposure
  13. 800 VDC microturbine package with Microgrids 4 AI targets direct DC campus power; design validation precedes deployment

    emerging
    CEPL · USExposure

Sources: gevernova.com, siemens-energy.com, oracle.com, tallgrass.com, capstoneenergyplus.com, doosan.com

Dedicated power services

Developers and operators build or rent generation behind the meter when utility connections arrive too late. Contracts can include bridge power, long-term operation, batteries and fuel coordination.

Heat (est.)
  1. Oracle collaboration targets 2.3 GW of dedicated gas power using INNIO engines and ABB electrical systems

    leader
    Private · USExposure
  2. Long-term data center power contracts include a roughly 660 MW Hatchbo deployment and new multi-hundred-MW capacity

    major
    SEI · USExposure
  3. Liberty Power Innovations and Vantage plan up to 1 GW; 400 MW of capacity is reserved for 2027 deployment

    major
    LBRT · USExposure
  4. PROPWR's 60 MW Midwest hyperscaler contract pairs gas generation with storage for dynamic data center loads

    challenger
    PUMP · USExposure
  5. Microsoft's San Jose backup project contracts about 100 MW of renewable-gas microgrid capacity

    major
    EROC · USExposure
  6. Will-Power's Socrates North and South facilities target dedicated Ohio data center service during late 2026

    challenger
    WMB · USExposure
  7. Modular gas generators and batteries provide rental bridge power while data centers await permanent grid service

    major
    Private · GBExposure
  8. Five awarded data center power projects and a greater-than-1 GW advanced pipeline expand on-site energy services

    challenger
    AMRC · USExposure
  9. A five-year 120 MW private-generation PPA targets first-half 2027 energization, with bridge power already supplied

    challenger
    AESI · USExposure
  10. NovaLT turbine orders approaching 1 GW support planned dedicated data center power-service entry

    emerging
    KGS · USExposure
  11. Snyder's initial 8 MW Crusoe Spark campus is under construction, with first operation targeted for early 2027

    emerging
    NRGV · USExposure
  12. Integrates and operates campus power controls and storage for Crusoe under the same AI UPS deployment agreement

    challenger
    Private · USExposure
  13. PowerSecure contracted backup generation, controls and peak-shaving support for Keel's Moses Lake AI campus in September 2026

    niche
    SO · USExposure

Sources: voltagrid.com, investors.libertyenergy.com, ir.propetroservices.com, williams.com, finance.yahoo.com, crusoe.ai

Facility batteries & storage

Larger stationary batteries buffer abrupt AI loads, support islanded campus generation and bridge power interruptions. This segment covers facility BESS; short-duration UPS cells and cabinets are listed separately.

Heat (est.)
  1. Megapack installations buffer xAI Colossus electrical demand; this is site storage, not a server-rack battery

    leader
    TSLA · USExposure
  2. Smartstack storage supports islanded and grid-connected data center power, including gas-plus-battery architectures

    challenger
    FLNC · USExposure
  3. Z3 zinc storage enters Frontier Power USA's 2 GWh reservation spanning data center, utility and industrial projects

    emerging
    EOSE · USExposure
  4. GC Block grid-forming storage scales from 15.5 to 62 MWh; September 2026 launch targets data centers before deployment

    emerging
    1211.HK · HKEX · CNExposure
  5. PowerTitan 3.0 storage forms part of its 2026 AI grid-to-chip power architecture for large facilities

    challenger
    300274.SZ · SZSE · CNExposure
  6. 6.25 MWh LFP and 2.28 MWh sodium-ion platforms target energy shifting and rapid AI load buffering

    challenger
    Private · CNExposure
  7. Medium-voltage battery blocks provide ride-through and smooth AI load steps in the shared Crusoe campus deployment program

    challenger
    Private · USExposure
  8. September 2026 Infinite Grid capacity reservation targets Ontario edge-AI BESS deliveries in 2027

    emerging
    NEOV · USExposure

Sources: investor.enersys.com, zincfive.com, news.samsungsdi.com, news.lgensol.com, sec.gov, pv-magazine.com

HVDC & solid-state transformers

Higher-voltage DC architectures reduce repeated conversion and copper use between the facility feed and dense racks. Most 800 VDC and SST products are still in qualification or staged early deployment.

Heat (est.)
  1. Nvidia 800 VDC facility reference partner integrates rectification, distribution and thermal systems for next-gen racks

    leader
    VRT · USExposure
  2. Resilient Power SST technology, acquired in August 2025, supports its facility-to-rack 800 VDC development

    leader
    ETN · IEExposure
  3. Developing a 1.2 MW AC-to-800 VDC sidecar within its Nvidia-aligned next-generation facility power architecture

    major
    SU.PA · Euronext Paris · FRExposure
  4. Nvidia facility ecosystem partner develops medium-voltage conversion and protection for 800 VDC AI power delivery

    major
    ABBN.SW · SIX · CHExposure
  5. Reinhausen collaboration develops SST conversion from up to 36 kV AC to 800 VDC for AI facilities

    major
    SIE.DE · XETRA · DEExposure
  6. COMPUTEX 2026 SST demonstration converts medium-voltage AC to 800 VDC for future AI campus distribution

    major
    2308.TW · TWSE · TWExposure
  7. 800 VDC reference designs include SST prototypes up to 5 MW; commercial deployment remains in development

    major
    GEV · USExposure
  8. Energy unit's Nvidia collaboration develops grid-to-rack 800 VDC infrastructure and transformer integration

    major
    6501.T · TSE · JPExposure
  9. MEPPI develops centralized rectifiers and DC energy storage for Nvidia's future 800 VDC facility ecosystem

    major
    6503.T · TSE · JPExposure
  10. Heron Link 4.2 MW SST converts 34.5 kV AC to 800 VDC; volume production is targeted for late 2027

    emerging
    Private · USExposure
  11. SST power systems target early AI campus pilots following an $80 million Series A financing

    emerging
    Private · SGExposure
  12. Interport multiport SST joins Nvidia MGX; initial pre-certification 800 VDC units began shipping in 2026

    emerging
    Private · USExposure
  13. SL-DC superconducting feeders target up to 5 MW per circuit for high-current 800 VDC facility distribution

    emerging
    Private · USExposure
  14. Developing medium-voltage-to-800 VDC SST systems with Infineon solid-state circuit protection; no volume rollout yet

    emerging
    SEDG · ILExposure
  15. IQ SST modules are in development; full-system demonstrations target late 2026 and customer pilots 2027

    emerging
    ENPH · USExposure
  16. 240/336 V HVDC and Panama supplies ship to data centers; 800 V models remain in industrialization, not confirmed volume use

    major
    002364.SZ · SZSE · CNExposure
  17. Power-electronics unit reports four 13.8 kV AC-to-800 VDC SST orders for an overseas data center; delivery is not confirmed

    emerging
    601179.SS · SSE · CNExposure
  18. 10 kV, 2.4 MW silicon-carbide SST prototype targets direct facility conversion for AI data centers; commercial scale is unproven

    emerging
    688676.SS · SSE · CNExposure

Sources: developer.nvidia.com, eaton.com, press.siemens.com, heronpower.com, businesswire.com, investor.enphase.com

UPS batteries & cabinets

High-rate cells and battery cabinets supply seconds or minutes of facility UPS backup. Buyers qualify discharge power, operating temperature, fire protection and compatibility with the UPS vendor.

Heat (est.)
  1. DataSafe HX lead-acid batteries and newly available DataSafe Noir lithium systems support high-power UPS duty

    leader
    ENS · USExposure
  2. Pure Lead Max stationary batteries provide high-rate UPS discharge for data center backup strings

    major
    Private · USExposure
  3. Deka Fahrenheit VRLA batteries support warmer-running data center UPS installations

    major
    Private · USExposure
  4. Industrial lithium and lead-acid battery systems serve UPS backup, with expanding North American data center demand

    major
    6674.T · TSE · JPExposure
  5. High-rate lithium and lead backup batteries support AIDC UPS systems and telecom-to-data-center power expansion

    major
    300068.SZ · SZSE · CNExposure
  6. Lithium and lead-acid backup batteries supply Chinese data centers; Hong Kong listing began in August 2025

    major
    6960.HK · HKEX · CNExposure
  7. RU6 lithium battery cabinets provide up to 570 kW backup output for high-power AI data center UPS systems

    major
    0842.HK · HKEX · CNExposure
  8. BC2 and BC2 AI nickel-zinc cabinets surpassed 2 GW delivered or contracted capacity in April 2026

    challenger
    Private · USExposure
  9. Saft Flexion lithium UPS cabinets serve data centers; next-generation systems target initial delivery in 2027

    major
    TTE · FRExposure
  10. U8A1 LMO UPS batteries deliver 263 kW per rack for rapid high-power data center backup

    major
    006400.KS · KRX · KRExposure
  11. JP6 LFP UPS products shown in 2026 target high-rate data center backup alongside larger stationary storage

    challenger
    373220.KS · KRX · KRExposure
  12. LFP backup batteries supply high-power data center UPS configurations alongside containerized stationary storage

    major
    3750.HK · HKEX · CNExposure
  13. High-rate prismatic UPS cells target AI data center backup in its April 2026 end-to-end battery offering

    challenger
    300014.SZ · SZSE · CNExposure
  14. High-rate cells serve UPS backup for telecom sites and data centers; the cited share combines both markets

    major
    002074.SZ · SZSE · CNExposure>28% of telecom/DC UPS battery market, 2025 (est.)
  15. 85 Ah AIDC cell demonstrated at SNEC 2026 targets 10C continuous discharge; commercial installations are not established

    emerging
    0666.HK · HKEX · CNExposure
  16. PowerSafe EHP VRLA batteries provide high-rate discharge for institutional and data center UPS strings

    niche
    EXIDEIND.NS · NSE · INExposure
  17. SCiB lithium-titanate batteries provide high-rate discharge and long cycle life for UPS backup cabinets

    niche
    Private · JPExposure
  18. EnergyCore Li5 and Li7 lithium-ion battery cabinets supply short-duration high-power discharge to facility UPS systems

    major
    VRT · USExposure
  19. Galaxy lithium-ion cabinets hold 10-17 battery modules and integrate with three-phase facility UPS systems

    major
    SU.PA · Euronext Paris · FRExposure

Sources: evebattery.com, prnewswire.com, vertiv.com, se.com, exideindustries.com, global.toshiba

Glossary

UPS
Uninterruptible power supply: bridges disturbances and outages until generators or other power sources take over.
Switchgear
Breakers, busbars and controls that route electrical power and isolate faults.
Behind the meter
Generation or storage dedicated to a customer's facility rather than a general grid power station.
SST
Solid-state transformer: power electronics that combine voltage conversion with controllable AC or DC output.
BESS
Battery energy storage system: batteries, converters and controls used for backup, load smoothing or energy shifting.

Heat, spend, exposure and shares are editorial estimates. How to read the map ↗